Adhesion Degradation of the Metallization-Encapsulant Interface

Nicholas Bosco, Peter Hacke, Sarah Kurtz, Jared Tracy, Reinhold Dauskardt

Research output: Contribution to conferencePaper

Abstract

Adhesion of the silver metallization/ encapsulant interface was measured through temperature, humidity and voltage bias stress. Results indicate that adhesion at this interface is severely compromised by even short exposures to humidity and quickly plateaus with further, prolonged, exposure. The magnitude of degradation is also identical to that measured through a three-month outdoor, on-sun, exposure. While the addition of a voltage bias also appears capable of further degrading adhesion below this plateau level, in the absence of humidity, adhesion may be similarly degraded.
Original languageAmerican English
Pages1336-1339
Number of pages4
DOIs
StatePublished - 2017
Event33rd European Photovoltaic Solar Energy Conference and Exhibition - Amsterdam, The Netherlands
Duration: 25 Sep 201729 Sep 2017

Conference

Conference33rd European Photovoltaic Solar Energy Conference and Exhibition
CityAmsterdam, The Netherlands
Period25/09/1729/09/17

NREL Publication Number

  • NREL/CP-5K00-67977

Keywords

  • degradation
  • encapsulation
  • metallization
  • reliability
  • screen printing

Fingerprint

Dive into the research topics of 'Adhesion Degradation of the Metallization-Encapsulant Interface'. Together they form a unique fingerprint.