Comparison of Pyranometers vs. PV Reference Cells for Evaluation of PV Array Performance

Lawrence Dunn, Michael Gostein, Keith Emery

Research output: Contribution to conferencePaperpeer-review

51 Scopus Citations

Abstract

As the photovoltaics (PV) industry has grown, the need for accurately monitoring the solar resource of PV power plants has increased. Historically, the PV industry has relied on thermopile pyranometers for irradiance measurements, and a large body of historical irradiance data taken with pyranometers exists. However, interest in PV reference devices is increasing. In this paper, we discuss why PV reference devices are better suited for PV applications, and estimate the typical uncertainties in irradiance measurements made with both pyranometers and PV reference devices. We assert that the quantity of interest in monitoring a PV power plant is the equivalent irradiance under the IEC 60904-3 reference solar spectrum that would produce the same electrical response in the PV array as the incident solar radiation. For PV-plant monitoring applications, we find the uncertainties in irradiance measurements of this type to be on the order of ±5% for thermopile pyranometers and ±2.4% for PV reference devices.

Original languageAmerican English
Pages2899-2904
Number of pages6
DOIs
StatePublished - 2012
Event38th IEEE Photovoltaic Specialists Conference, PVSC 2012 - Austin, TX, United States
Duration: 3 Jun 20128 Jun 2012

Conference

Conference38th IEEE Photovoltaic Specialists Conference, PVSC 2012
Country/TerritoryUnited States
CityAustin, TX
Period3/06/128/06/12

NREL Publication Number

  • NREL/CP-5200-57521

Keywords

  • calibration
  • energy resources
  • instrumentation and measurement
  • measurement uncertainty
  • photovoltaic cells

Fingerprint

Dive into the research topics of 'Comparison of Pyranometers vs. PV Reference Cells for Evaluation of PV Array Performance'. Together they form a unique fingerprint.

Cite this