TY - GEN
T1 - Degradation in PV Encapsulation Strength of Attachment: An Interlaboratory Study Towards a Climate-Specific Test
T2 - NREL (National Renewable Energy Laboratory)
AU - Miller, David
AU - Kempe, Michael
AU - Annigoni, Eleonora
AU - Ballion, Amal
AU - Bokria, Jayesh
AU - Bruckman, Laura
AU - Burns, David
AU - Chen, Xinxin
AU - Feng, Jiangtao
AU - French, Roger
AU - Fowler, Sean
AU - Honeker, Christian
AU - Khonkar, Hussam
AU - Kohl, Michael
AU - Perret-Aebi, Laure-Emmanuelle
AU - Phillips, Nancy
AU - Scott, Kurt
AU - Sculati-Meillaud, Fanny
PY - 2016
Y1 - 2016
N2 - Reduced strength of attachment of the encapsulant resulting from the outdoor environment, including ultraviolet (UV) radiation, may decrease photovoltaic (PV) module lifetime by enabling widespread corrosion of internal components. To date, few studies exist showing how the adhesion of PV components varies with environmental stress. We have conducted an interlaboratory experiment to provide an understanding that will be used to develop climatic specific module tests. Factors examined in the study included the UV light source (lamp type), temperature, and humidity to be proposed for use in accelerated aging tests. A poly (ethylene-co-vinyl acetate) (EVA) formulation often used in veteran PV installations was studied using a compressive shear test - to quantify the strength of attachment at the EVA/glass interface. Replicate laminated glass/polymer/glass coupon specimens were weathered at 12 institutions using a variety of indoor chambers or field aging. Shear strength, shear strain, and toughness were measured using a mechanical load-frame for the compressive shear test, with subsequent optical imaging and electron microscopy of the separated surfaces.
AB - Reduced strength of attachment of the encapsulant resulting from the outdoor environment, including ultraviolet (UV) radiation, may decrease photovoltaic (PV) module lifetime by enabling widespread corrosion of internal components. To date, few studies exist showing how the adhesion of PV components varies with environmental stress. We have conducted an interlaboratory experiment to provide an understanding that will be used to develop climatic specific module tests. Factors examined in the study included the UV light source (lamp type), temperature, and humidity to be proposed for use in accelerated aging tests. A poly (ethylene-co-vinyl acetate) (EVA) formulation often used in veteran PV installations was studied using a compressive shear test - to quantify the strength of attachment at the EVA/glass interface. Replicate laminated glass/polymer/glass coupon specimens were weathered at 12 institutions using a variety of indoor chambers or field aging. Shear strength, shear strain, and toughness were measured using a mechanical load-frame for the compressive shear test, with subsequent optical imaging and electron microscopy of the separated surfaces.
KW - degradation
KW - durability
KW - photovoltaic encapsulation
KW - reliability
KW - xenon
M3 - Presentation
T3 - Presented at the 2016 IEEE 43rd Photovoltaic Specialists Conference (PVSC), 5-10 June 2016, Portland, Oregon
ER -