This research addresses the question of what are the energy consequences for oversizing of an air conditioner in a home. Conventional wisdom holds that oversizing the AC results in significant energy penalties. However, the reason for this was shown to be due to crankcase heaters and not due to cycling performance of the AC, and is only valid for a particular set of assumptions. Adding or removing individual characteristics, such as ducts or crankcase heaters, can have measurable impacts on energy use. However, with all other home characteristics held constant, oversizing the AC generally has a small effect on cooling energy use, even if the cycling performance of the unit is poor. The relevant aspects of air conditioner modeling are discussed to illustrate the effects of the cycling loss coefficient, Cd, capacity, climate, ducts and parasitic losses such as crankcase heaters. A case study of a typical 1960's vintage home demonstrates results in the context of whole building simulations using EnergyPlus.
Original languageAmerican English
Number of pages22
DOIs
StatePublished - 2014

NREL Publication Number

  • NREL/TP-5500-60801

Keywords

  • AC
  • air conditioners
  • Building America
  • crankcase
  • ducts
  • energy use
  • NREL
  • oversize
  • residential
  • residential buildings

Fingerprint

Dive into the research topics of 'Energy Impacts of Oversized Residential Air Conditioners -- Simulation Study of Retrofit Sequence Impacts'. Together they form a unique fingerprint.