Evaluation of the Effective Moisture Penetration Depth Model for Estimating Moisture Buffering in Buildings

Research output: NRELTechnical Report

Abstract

This study examines the effective moisture penetration depth (EMPD) model, and its suitability for building simulations. The EMPD model is a compromise between the simple, inaccurate effective capacitance approach and the complex, yet accurate, finite-difference approach. Two formulations of the EMPD model were examined, including the model used in the EnergyPlus building simulation software. Anerror in the EMPD model we uncovered was fixed with the release of EnergyPlus version 7.2, and the EMPD model in earlier versions of EnergyPlus should not be used.
Original languageAmerican English
Number of pages33
DOIs
StatePublished - 2013

NREL Publication Number

  • NREL/TP-5500-57441

Keywords

  • building simulation test cases
  • effective capacitance (EC) model
  • EnergyPlus
  • National Renewable Energy Laboratory (NREL)
  • simulation software

Fingerprint

Dive into the research topics of 'Evaluation of the Effective Moisture Penetration Depth Model for Estimating Moisture Buffering in Buildings'. Together they form a unique fingerprint.