Evaluation of Two CEDA Weatherization Pilot Implementations of an Exterior Insulation and Over-Clad Retrofit Strategy for Residential Masonry Buildings in Chicago

Research output: NRELSubcontract Report

Abstract

This project examines the implementation of an exterior insulation and over-clad strategy for brick masonry buildings in Chicago. The strategy was implemented at a free-standing two story two-family dwelling and a larger free-standing multifamily building. The test homes selected for this research represent predominant housing types for the Chicago area. High heating energy use typical in thesebuildings threaten housing affordability. Uninsulated mass masonry wall assemblies also have a strongly detrimental impact on comfort. Significant changes to the performance of masonry wall assemblies is generally beyond the reach of typical weatherization (Wx) program resources. The Community and Economic Development Association of Cook County, Inc. (CEDA) has secured a Sustainable EnergyResources for Consumers (SERC) innovation grant sponsored by the United States Department of Energy (DOE). This grant provides CEDA the opportunity to pursue a pilot implementation of innovative approaches to retrofit in masonry wall enclosures. The exterior insulation and over-clad strategy implemented through this project was designed to allow implementation by contractors active in CEDAweatherization programs and using materials and methods familiar to these contractors. The retrofit measures are evaluated in terms of feasibility, cost and performance. Through observations of the strategies implemented, the research described in this report identifies measures critical to performance as well as conditions for wider adoption. The research also identifies common factors thatmust be considered in determining whether the exterior insulation and over-clad strategy is appropriate for the building.
Original languageAmerican English
Number of pages106
StatePublished - 2013

Bibliographical note

Work performed by Building Science Corporation (BSC), Somerville, Massachusetts

NREL Publication Number

  • NREL/SR-5500-57989

Other Report Number

  • DOE/GO-102013-3904

Keywords

  • brick masonry
  • brick masonry retrofit
  • brick masonry retrofit strategy
  • brick retrofit
  • Building America
  • Building Science Corporation (BSC)
  • CEDA
  • Chicago
  • exterior insulation
  • exterior insulation retrofit
  • high performance retrofit
  • masonry over-clad
  • masonry retrofit
  • overclad
  • residential
  • residential buildings
  • weatherization

Fingerprint

Dive into the research topics of 'Evaluation of Two CEDA Weatherization Pilot Implementations of an Exterior Insulation and Over-Clad Retrofit Strategy for Residential Masonry Buildings in Chicago'. Together they form a unique fingerprint.