Internal Roof and Attic Thermal Radiation Control Retrofit Strategies for Cooling-Dominated Climates

Charles Booten, Chuck Booten (NREL Technical Monitor)

Research output: NRELSubcontract Report

Abstract

This project evaluates the cooling energy savings and cost effectiveness of radiation control retrofit strategies for residential attics in U.S. cooling-dominated climates. Usually, in residential applications, radiation control retrofit strategies are applied below the roof deck or on top of the attic floor insulation. They offer an alternative option to the addition of conventional bulkinsulation such as fiberglass or cellulose insulation. Radiation control is a potentially low-cost energy efficiency retrofit strategy that does not require significant changes to existing homes. In this project, two groups of low-cost radiation control strategies were evaluated for southern U.S. applications. One uses a radiant barrier composed of two aluminum foils combined with an enclosedreflective air space and the second uses spray-applied interior radiation control coatings (IRCC).
Original languageAmerican English
Number of pages72
StatePublished - 2013

Bibliographical note

Work performed by Fraunhoger CSE, Cambridge, Massachusetts

NREL Publication Number

  • NREL/SR-5500-58714

Other Report Number

  • DOE/GO-102013-3943

Keywords

  • attics
  • Building America
  • Fraunhofer
  • radiant barrier
  • radiation control
  • residential
  • residential buildings
  • retrofit strategies

Fingerprint

Dive into the research topics of 'Internal Roof and Attic Thermal Radiation Control Retrofit Strategies for Cooling-Dominated Climates'. Together they form a unique fingerprint.