Abstract
This paper provides the changes in performance ratings of two photovoltaic (PV) systems located on the roof of the Solar Energy Research Facility (SERF) building at the National Renewable Energy Laboratory (NREL) in Golden, Colorado. For the period of May 1994 to April 2002, the performance rating of the two PV systems decreased at the rate of 1% per year. Most of the changes in performancerating are attributed to changes in the performance of the PV arrays. But about a fifth of the observed changes were from the inverter not tracking the peak-power as effectively as the PV arrays aged.
Original language | American English |
---|---|
Number of pages | 6 |
State | Published - 2003 |
Event | National Center for Photovoltaics (NCPV) and Solar Program Review Meeting - Denver, Colorado Duration: 24 Mar 2003 → 26 Mar 2003 |
Conference
Conference | National Center for Photovoltaics (NCPV) and Solar Program Review Meeting |
---|---|
City | Denver, Colorado |
Period | 24/03/03 → 26/03/03 |
NREL Publication Number
- NREL/CP-520-33531
Keywords
- inverter
- peak-power tracking
- performance rating
- photovoltaic systems
- PV array
- SERF