MC Formula Protocol for H35HF Fueling: Cooperative Research and Development Final Report, CRADA Number CRD-20-17412

Research output: NLRTechnical Report

Abstract

The National Renewable Energy Lab (NREL), Frontier Energy, and the industry partners worked together to help SAE J2601-5 develop an H35 high-flow (HF) medium-duty (MD) and heavy-duty (HD) fueling protocol. The team upgraded NREL's hydrogen filling simulations (H2FillS) model to accommodate an MC Formula fueling (t-final) table generation capability by leveraging NREL's high-performance computing system. Based on protocol boundary conditions (e.g., allowable maximum flow rate, range of storage system size) set by SAE J2601-5, the team generated the fueling tables and then validated the reliability of those tables by installing them on NREL's HD dispenser and ZBT's H35HF dispenser and then performing H35HF fueling experiments. Through the validation process, this team certified that the fueling tables generated were reliable to install in commercial H35HF dispensers and then performed H35HF fueling of commercial MD/HD vehicles.
Original languageAmerican English
Number of pages27
DOIs
StatePublished - 2025

NLR Publication Number

  • NREL/TP-5700-95350

Keywords

  • CRADA
  • defueling
  • fueling protocol
  • OEM

Fingerprint

Dive into the research topics of 'MC Formula Protocol for H35HF Fueling: Cooperative Research and Development Final Report, CRADA Number CRD-20-17412'. Together they form a unique fingerprint.