Measure Guideline: Implementing a Plenum Truss for a Compact Air Distribution System

Research output: NRELSubcontract Report

Abstract

This Measure Guideline presents the steps to implement a compact duct system inside an attic bulkhead (plenum truss) of a one-story, slab-on-grade (SOG) home. In a compact duct design, ductwork runs are reduced in length to yield a smaller and more compact duct system. Less energy will be lost through ductwork if the ducts are contained within the thermal enclosure of the house. These measuresare intended for the production builder working to meet the 2012 International Energy Conservation Code (IECC) requirements and keep the ductwork within the thermal enclosure of the house. This measure of bringing the heating, ventilation and air conditioning (HVAC) equipment and ductwork within the thermal enclosure of the house is appropriate for the builder wishing to avoid cathedralizing theinsulation in the attic space (i.e., locating it at the underside of the roof deck rather than along the attic floor) or adding dropped soffits.
Original languageAmerican English
Number of pages27
StatePublished - 2013

Bibliographical note

Work performed by IBACOS, Inc., Pittsburgh, Pennsylvania

NREL Publication Number

  • NREL/SR-5500-60056

Other Report Number

  • DOE/GO-102013-4017

Keywords

  • compact air distribution systems
  • compact duct system
  • heating, ventilation, and air conditioning (HVAC)
  • insulation
  • plenum truss
  • reverse attic bulkhead

Fingerprint

Dive into the research topics of 'Measure Guideline: Implementing a Plenum Truss for a Compact Air Distribution System'. Together they form a unique fingerprint.