Abstract
Site survey data for several residential installations are provided, showing the extent and frequency of shade throughout the year. This background information is used to design a representative shading test that is conducted on two side-by-side 8-kW photovoltaic (PV) installations. One system is equipped with a standard string inverter, while the other is equipped with microinverters on eachsolar panel. Partial shade is applied to both systems in a comprehensive range of shading conditions, simulating one of three shade extents. Under light shading conditions, the microinverter system produced the equivalent of 4% annual performance improvement, relative to the string inverter system. Under moderate shading conditions, the microinverter system outperformed the string invertersystem by 8%, and under heavy shading the microinverter increased relative performance by 12%. In all three cases, the percentage of performance loss that is recovered by the use of distributed power electronics is 40%-50%. Additionally, it was found that certain shading conditions can lead to additional losses in string inverters due to peak-power tracking errors and voltage limitations.
Original language | American English |
---|---|
Number of pages | 8 |
State | Published - 2012 |
Event | 2012 IEEE Photovoltaic Specialists Conference - Austin, Texas Duration: 3 Jun 2012 → 8 Jun 2012 |
Conference
Conference | 2012 IEEE Photovoltaic Specialists Conference |
---|---|
City | Austin, Texas |
Period | 3/06/12 → 8/06/12 |
NREL Publication Number
- NREL/CP-5200-54039
Keywords
- DC-DC power converters
- microinverters
- mismatch
- partial shading
- photovoltaic systems