Abstract
Data for thousands of systems by multiple sources were transmitted to NREL for evaluation. Initial automated data quality assurance (QA) checks identified hundreds of systems (QA Tier 1) with high-quality meteorological and AC production data and hundreds of QA Tier 2 systems with adequate data quality. A standard RdTools analysis was conducted for these systems, evaluating performance loss on an annualized basis. To date with the systems evaluated so far, we find a median performance loss rate (aka Rd or degradation rates) for the entire fleet of -0.72%/year based on individual inverter data, which is in line with historical degradation rates previously published for modules and systems (-0.5% to -0.9% / yr, Jordan et al. 2016). A fleet-scale distribution based on revenue-grade meter data rather than inverter AC (alternating current) data yields a slightly different result. We are working to understand the difference between this result and the inverter-based result of -0.72%/year.
Original language | American English |
---|---|
Number of pages | 24 |
DOIs | |
State | Published - 2020 |
NREL Publication Number
- NREL/TP-5K00-76687
Keywords
- degradation
- performance
- photovoltaic
- PV