Results from Testing and Modeling Residential Load-Side Heat Exchangers

R. B. Farrington, C. E. Bingham

Research output: Contribution to conferencePaperpeer-review

Abstract

The measurement and modeling of immersed coil heat exchangers used in residential solar domestic hot water systems is discussed. Two smooth-coil and two finned-coil heat exchangers, with heat transfer areas of 1. 7 and 2. 5 m**2, were tested. The measured U-values ranged from 100 W/m**2 at low temperature differences to as high as 1200 W/m**2 at high temperature differences. The analytical model developed agreed reasonably well with the experimental results.

Original languageAmerican English
Pages1-10
Number of pages10
StatePublished - 1988
EventSolar Engineering-1988: Tenth Annual ASME Solar Energy Conference - Denver, Colorado
Duration: 10 Apr 198814 Apr 1988

Conference

ConferenceSolar Engineering-1988: Tenth Annual ASME Solar Energy Conference
CityDenver, Colorado
Period10/04/8814/04/88

NREL Publication Number

  • ACNR/CP-254-10377

Fingerprint

Dive into the research topics of 'Results from Testing and Modeling Residential Load-Side Heat Exchangers'. Together they form a unique fingerprint.