Technical Evaluation of Two 6-kW Mono-Si Photovoltaic Systems at the National Renewable Energy Laboratory

    Research output: Contribution to conferencePaper

    Abstract

    This document presents an analysis of performance data on the two 6-kWac grid-connected photovoltaic systems at the National Renewable Energy Laboratory (NREL). The performance parameters analyzed included dc and ac power, aperture efficiency, energy, capacity factor and performance index which are compared to plane-of-array irradiance, ambient temperature, and back-of-module temperature as afunction of time, either daily or monthly. Power ratings of the systems were also obtained for data corresponding to different test conditions. This study has shown, in addition to expected seasonal trends, that system monitoring is a valuable tool in assessing performance and detecting faulty equipment. In addition, methods applied for this study may be used to evaluate and compare systemsemploying different cell technologies.
    Original languageAmerican English
    Pages1533-1536
    Number of pages4
    DOIs
    StatePublished - 1996
    EventTwenty Fifth IEEE Photovoltaic Specialists Conference - Washington, D.C.
    Duration: 13 May 199617 May 1996

    Conference

    ConferenceTwenty Fifth IEEE Photovoltaic Specialists Conference
    CityWashington, D.C.
    Period13/05/9617/05/96

    NREL Publication Number

    • NREL/CP-22533

    Fingerprint

    Dive into the research topics of 'Technical Evaluation of Two 6-kW Mono-Si Photovoltaic Systems at the National Renewable Energy Laboratory'. Together they form a unique fingerprint.